AR – 051 Toshiba Split Air Conditioning System 2.5kW – 14kW

£5,151.60£18,465.60 Excl. VAT & Shipping

Our ATEX explosion-safe air conditioners are based on the Toshiba range of air conditioners and are made to safely ensure a good climate in an area where a release of gas, vapor or mist could possibly cause an explosive atmosphere (Zone 2). The units are widely used in office spaces, offshore temporary living quarters, crane cabins and at the storage of chemicals and flammable substances.

Description

Our explosion-safe air conditioners are based on the Toshiba range of air conditioners and are made to safely ensure a good climate in an area where a release of gas, vapor or mist could possibly cause an explosive atmosphere (Zone 2). The units are widely used in office spaces, offshore temporary living quarters, crane cabins and at the storage of chemicals and flammable substances.

Depending on the required power, a wall-mounted or ceiling-mounted indoor unit can be selected. Duct or cassette model indoor units can also be supplied on request. Multisplit versions are also among the extensive options.

The ATEX Split air conditioners are explosion-safe and certified in accordance with European directive 2014/34/EU (ATEX 114) and are CE marked. The systems can consist of a combination of explosion-safe and non-explosion-safe units, depending on the zoning of the area where the units are placed. During the conversion of the units to explosion-safe, the greatest possible attention is given to the maintainability and ease with which the units can be installed. The functionality remains completely intact.

For placement in a corrosive environment, a number of corrosion-resistant versions are available with factory coated condenser fins and copper tubing and additional coating of the sheet steel plating. Standard units can also be provided with an additional protective coating. In addition to Toshiba’s systems, we can also convert systems from other manufacturers to explosion-safe. Ask for the possibilities.

 

FEATURES
  • Based upon the Toshiba RAV range of air conditioning systems
  • ATEX certified
  • Explosion-safe for gasses and vapours, suitable for use in Zone 2
  • From 2,5 up to 14 kW, cooling and heating (heatpump function)
  • Ambient temperatures from -27 °C up to +52 °C
  • Industrial, compact and corrosion resistant executions
  • Optional coating of the condensor fins and copper tubing
  • Any combination of explosion-safe and non explosion-safe parts can be made
TECHNICAL PROPERTIES
  • Explosion safety (outdoor unit):
    II 3 G Ex ec h ic mc IIC T3 Gc
  • Explosion safety (indoor unit):
    II 3 G Ex ec h ic IIC T4 Gc
  • Explosion safety (remote control):
    II 3 G Ex ic IIC T6 Gc
  • European directives:
    2014/34/EU (ATEX 114), 2014/30/EU (EMC) and 2009/125/EC (EcoDesign)
  • Applied standards:
    EN 60079-0:2018, EN 60079-7:2015 / A1:2018, EN 60079-11:2012, EN 60079-18:2015 / A1:2017, EN 80079-36:2016 and EN 80079-37:2016
  • Certification:
    EU Declaration of Conformity / Unit Assessment Certificate
  • Power supply:
    220 – 240 VAC / 380 – 415 VAC
  • Mains frequency:
    50 / 60 Hz (model dependent)
  • Ambient temperature:
    -27 °C to +52 °C

Additional information

Selection

2.5kW Wall Mounted – 230V/1Ph/50-60Hz, 2.5kW Ceiling Mounted – 230V/1Ph/50-60Hz, 2.5kW Ducted – 230V/1Ph/50-60Hz, 3.6kW Wall Mounted – 230V/1Ph/50-60Hz, 3.6kW Ceiling Mounted – 230V/1Ph/50-60Hz, 3.6kW Ducted – 230V/1Ph/50-60Hz, 5.0kW Wall Mounted – 230V/1Ph/50-60Hz, 5.0kW Ceiling Mounted – 230V/1Ph/50-60Hz, 5.0kW Ducted – 230V/1Ph/50-60Hz, 6.7kW Wall Mounted – 230V/1Ph/50-60Hz, 6.9kW Ceiling Mounted – 230V/1Ph/50-60Hz, 6.7kW Ducted – 230V/1Ph/50-60Hz, 8.0kW Wall Mounted – 230V/1Ph/50-60Hz, 8.0kW Ceiling Mounted – 230V/1Ph/50-60Hz, 8.0kW Ducted – 230V/1Ph/50-60Hz, 9.5kW Wall Mounted – 230V/1Ph/50-60Hz, 9.5kW Wall Mounted – 400V/3Ph/50-60Hz, 9.5kW Ceiling Mounted – 230V/1Ph/50-60Hz, 9.5kW Ducted – 230V/1Ph/50-60Hz, 12.1kW Ceiling Mounted – 230V/1Ph/50-60Hz, 12.1kW Ducted – 230V/1Ph/50-60Hz, 14.0kW Ceiling Mounted – 400V/3Ph/50Hz